Objective
The objective of the audit was to verify that integrity and barrier management for flexible risers and systems for pressure safety/emergency shutdown complied with the company's own requirements and statutory regulations.
Result
Three non-conformities were identified in connection with:
In addition, two improvement points were identified in connection with:
Equinor has been given a deadline of 20 August 2018 to report on how the non-conformities and improvement points will be addressed.