Gå til hovedinnhold

Audit of Equinor – Statfjord C

From 23 April to 30 May 2018, we carried out an audit of Equinor’s follow-up of the preconditions for consent to expand the lifetime of Statfjord C (SFC).


Objective
The objective of the audit was to verify how factors described in the consent application and the preconditions for consent are being followed up by Equinor and whether this has led to improvements in health, safety and the environment on the facility.

Result
Non-conformities were identified in connection with:

  • The fire water system
  • Penetrations in fire walls
  • Noise exposure
  • Chemical health hazards

In addition, improvement points were identified in connection with:

  • Inspection of penetrations in fire walls
  • Updating of technical operating documents
  • Fire divisions
  • Ergonomic factors
  • Employee participation

Equinor has been given a deadline of 31 August 2018 to report on how the non-conformities and improvement points will be addressed.