Gå til hovedinnhold

Audit of flexible riser fabrication for Gina Krog FSO

On 21 and 22 September 2015, the Petroleum Safety Authority Norway carried out an audit of Statoil and the fabrication of flexible risers for Gina Krog FSO.


The objective of the audit was to monitor the fabrication of flexible risers, follow up the operator and supplier/subcontractor and verify that the project is being planned and executed in compliance with regulatory requirements.

Result
No non-conformities were identified.

Two improvement points were identified in connection with document management, and responsibility and authority.

Statoil has been given a deadline of 10 November 2015 to report on how the improvement points will be dealt with.

Avvik:
Innebærer at et forhold er vurdert ikke å være i samsvar med krav i regelverket.

Forbedringspunkt:
Innebærer at vi har påvist en mangel eller svakhet, men hvor det ikke er tilstrekkelig grunnlag for å fastslå brudd på regelverkskrav.


 

 

Øyvind Midttun, Press contact
Email: oyvind.midttun@ptil.no | +47 51 87 34 77