Gå til hovedinnhold

Audit of Stena Drilling AS – Stena Don

From 19 to 22 September 2016, the PSA carried out an audit of the blowout preventer (BOP) and control functions on Stena Don following upgrading and installation of a new BOP.


The objective of the audit was to verify that the company is compliant with the regulatory requirements relating to BOP operations, control functions, testing, maintenance and reporting.

Result
One non-conformity was identified in connection with maintenance management.

Furthermore, three improvement points were identified concerning BOP reliability requirements, the anti-collision system and knowledge of major accident risk.

Stena Drilling AS has been given a deadline of 11 November 2016 to report on how the non-conformity and improvement points will be dealt with. 

Øyvind Midttun, Press contact
Email: oyvind.midttun@ptil.no | +47 51 87 34 77